Air Condition Control Panel
API Documentation: AC Panel API
Description
The air conditioning system operation is fully automatic and refreshes air constantly and maintains temperature in the aircraft.
The two air conditioning packs (PACK 1+2) operate automatically and independently of each other.
Usage
COCKPIT, FWD CABIN, AFT CABIN
- 12 o'clock position : 24°C (76°F).
- COLD position : 18°C (64°F).
- HOT position : 30°C (86°F).
HOT AIR
- ON:
- Hot air is provided
- OFF:
- Hot air valve is closed. FAULT is reset.
- FAULT:
- Amber light and ECAM caution when overheat is detected. (> 88°C/190°F). Valves close automatically. Below 70°C (158°F) or if the flight crew selects OFF the FAULT light goes OFF.
PACK 1 + 2
- ON:
- The pack flow control valve is automatically controlled.
- OFF:
- The pack flow control valve closes.
- FAULT:
- Amber light and ECAM caution if the pack flow control valve position disagrees with the selected position, or in the case of compressor outlet overheat or pack outlet overheat.
PACK FLOW selector
- Permits the selection of pack valve flow, according to the number of passengers and ambient conditions (smoke removal, hot or wet conditions).
- LO (80 %) - NORM (100 %) - HI (120 %).
- Irrelevant in single pack operation, or with APU bleed supply. Always HI in these cases.
- If cooling demand cannot be satisfied will go to 100% even when setting is LO.
RAM AIR (guarded)
- ON:
- The RAM air inlet opens.
- If Δp >= 1 psi: The outflow valve control remains normal. No emergency RAM air flows in.
- If Δp < 1 psi: The outflow valve opens to about 50 % when under automatic control. It does not automatically open when it is under manual control. Emergency RAM airflow is directly supplied to the mixer unit.
- When DITCHING is pressed this is closed.
- OFF:
- The RAM air inlet closes.
Currently not available or INOP in the FBW A32NX for Microsoft Flight Simulator.
ENG 1 and ENG 2 BLEED
- ON:
- Bleed pressure is provided
- FAULT:
- Amber light and an ECAM caution, if:
- overpressure downstream of the bleed valve.
- bleed air overheat.
- wing or engine leak on the related side.
- bleed valve is not closed during engine start.
- bleed valve is not closed with APU bleed ON. It goes out when the ENG BLEED pushbutton switch is OFF or if the fault has disappeared.
- Amber light and an ECAM caution, if:
- OFF:
- The bleed valve and HP valve close. White OFF light comes on.
APU BLEED
- ON:
- The APU valve opens if APU N >95 %. The blue ON light comes on.
- OFF:
- The APU valve closes.
- FAULT:
- Amber light and an ECAM caution, when the system detects an APU leak.
X-BLEED selector
- AUTO:
- Crossbleed valve is open if the APU bleed valve is open. It is closed if the APU bleed valve is closed or, in case of a wing, pylon, or APU leak (except during engine start).
- OPEN:
- Crossbleed valve is open.
- CLOSE:
- Crossbleed valve is closed.
Last update:
June 11, 2022